Cảm biến Kyoritsu 8129 đo 30 - 300A cho đồng hồ Kyoritsu 5010/5020, 6300, 6305, 6310, 6315
Mã sản phẩm: 8129
Giá bán : Liên hệ
Hãng sản xuất: Kyoritsu
Bảo hành: 12 tháng
Xuất xứ: Còn hàng
Chia sẻ sản phẩm này với bạn bè:
Cảm biến Kyoritsu 8129 đo 30 - 300A cho đồng hồ Kyoritsu 5010/5020, 6300, 6305, 6310, 6315
Mã hàng : 8129 , K8129 , Kyoritsu 8129
 |
Flexible Clamp Sensor |
 |
8129 |
|
|
|
 |
8129-01 (for 1ch) |
 |
8129-02 (for 2ch) |
 |
8129-03 (for 3ch) |
• |
Flexible for various test fields |
• |
Can measure AC current up to 3000A |
• |
Flexible and light weight by the air core coil used at the sensor part |
• |
Measurable conductor size:
max Φ150mm |
• |
Designed to meet the international safety standard
IEC 61010-1 CAT III 600V |
|

 |

* |
When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors. |
|
 |
 |
8129-01 (for 1ch) |
8129-02 (for 2ch) |
8129-03 (for 3ch) |
Conductor size |
max. Φ150mm |
Rated current |
300/1000/3000A |
Output voltage |
300A Range |
: |
AC500mV/AC300A (1.67mV/A) |
1000A Range |
: |
AC500mV/AC1000A (0.5mV/A) |
3000A Range |
: |
AC500mV/AC3000A (0.167mV/A) |
|
Accuracy |
|±1.0%rdg (45 - 65Hz) |
Phase Shift |
within ±1° |
Withstand voltage |
AC5350V for 5 seconds |
300A Range |
: |
30 - 300A (45 - 65Hz) |
1000A Range |
: |
100 - 1000A (45 - 65Hz) |
3000A Range |
: |
300 - 3000A (45 - 65Hz) |
|
Cable length |
Sensor part : approx. 2m
Output cable : approx. 1m |
Output connector |
MINI DIN 6PIN |
Operating temperature & humidity ranges |
0 - 50ºC, relative humidity 85% or less (no condensation) |
Output impedance |
100Ω or less |
Applicable standards |
IEC 61010-1, IEC 61010-2-032 CAT III 600V Pollution degree2,
IEC 61326 |
Dimensions |
111(L) x 61(W) x 43(D) mm (except for protrusions) |
Weight |
Approx. 410g |
Approx. 680g |
Approx. 950g |
Accessories |
Instruction Manual
7199 (Output Cable) x1
9137 (Carrying Case) |
Instruction Manual
7199 (Output Cable) x2
9137 (Carrying Case) |
Instruction Manual
7199 (Output Cable) x3
9137 (Carrying Case) |
|
|